LabelSourcePropertySub-property ofRangeUsageVocab SchemaSyntax SchemaObligationExample: FaultExample: CapacitorExample 3Example 4Note
Category labelData Provider or ASPIRES.categoryID  Disturbance category label according to IEEE standard 1159-2009 Table 2  1Short duration RMS variations-Instantaneous-SagTransient-Oscillatory-Low frequency   
Category idData Provider or ASPIRES.categoryLabvelcategoryLabel  Disturbance category number or identifier according to IEEE standard 1159-2009 Table 21159-2009, table 2 12.1.11.2.1   
ROWS BELOW THIS ARE NOT CURRENTLY USED.    THE FIELDS BELOW REPEAT DATA FROM THE SOFTWARE ANALYSIS TABLE. HUMANS OR PROGRAMS SHOULD RETRIEVE RELEVANT FIELDS FROM THAT TABLE.        
Analysis ProviderData Provider or ASPIRES   Name of the entity/organization performing the IEEE disturbance analysis  1ElectrotekElectrotek   
Impulsive transient rise timeData Provider or ASPIRES   Transient rise time (in ns) (rise time: the time required for a pulse to rise to its peak value) http://grouper.ieee.org/groups/td/pq/documents/2010-01%20Power%20Quality%20Definitions%20Draft.pdf   0-1     
Impulsive transient durationData Provider or ASPIRES   Impulsive transient duration (in ns)  0-1     
FrequencyData Provider or ASPIRES   Frequency (in kHz)  0-1 1.395   
Oscillatory transient durationData Provider or ASPIRES   Duration of the oscillatory transient (in us)  0-1 0.0521 us (3.125 cycles)   
Oscillatory transient peak voltage magnitudeData Provider or ASPIRES   Voltage magnitude of the oscillatory transient (in per unit)  0-1 1.3193 (used absolute value)   
RMS voltage variation magnitudeData Provider or ASPIRES   RMS voltage variation magnitude (in per unit)  0-10.6813 pu    
RMS voltage variation durationData Provider or ASPIRES   RMS voltage variation duration (in cycles)  0-121. 6 cycles (0.36 sec)    
Current overload durationData Provider or ASPIRES   Duration of undervoltage caused by overload (in min) (question)  0-1     
Voltage imbalanceData Provider or ASPIRES   Ratio of the magnitude of the negative sequence component to the magnitude of the positive sequence component (in %) : % Imbalance = |Vneg|/|Vpos|*100  0-1     
Current imbalanceData Provider or ASPIRES   Ratio of the magnitude of the negative sequence component to the magnitude of the positive sequence component (in %) : % Imbalance = |Vneg|/|Vpos|*100  0-1     
Disturbance profile: DC offset Data Provider or ASPIRES   Magnitude (in %) Ratio of the magnitude of the DC component to the magnitude of the fundamental component (in %) (question) not described in IEEE Standard 1159...  0-1     
THDData Provider or ASPIRES   Total harmonic distortion (in %)  0-1     
InterharmonicData Provider or ASPIRES   magnitude (in %) : Ratio of the magnitude of the Interharmonic component to the magnitude of the fundamental component (in %) (question) not described in IEEE Standard 1159...  0-1     
Noise
Data Provider or ASPIRES   Signal-to-Noise ratio of the voltage or current (question)(in %) Method not recommendted to extract noise from the signal in IEEE Standard 1159...  0-1     
Voltage fluctuations frequencyData Provider or ASPIRES   Voltage fluctuations spectral content (in Hz)  0-1     
Voltage fluctuations magnitude (%)Data Provider or ASPIRES   Ratio of the magnitude of the modulation signal to the magnitude of the fundamental component (in %) (question) not described in IEEE Standard 1159...

 

: Magnitude for the voltage fluctuation can be defined as the rms magnitude of the modulation signal. This can be obtained by demodulating the waveform to remove the fundamental frequency and then measuring the magnitude of the modulation components. 

  0-1     
Voltage fluctuations magnitude (Pst index)Data Provider or ASPIRES   Flicker severity index Pst as defined in IEC 61000-4-15:2003 [B15] and IEEE Std 1453TM-2004 [B28].   0-1     
Power frequency variation durationData Provider or ASPIRES   Duration of the power frequency variation (in sec)  0-1     
Power frequency variation magnitudeData Provider or ASPIRES   Deviation of the power system fundamental frequency from its specified nominal value (e.g., 60Hz) (in Hz)   0-1