Versions Compared

Key

  • This line was added.
  • This line was removed.
  • Formatting was changed.

Schema Overview

Assumptions

...


 

Columns indicate:

 

Label: a human-readable label for the property
Source: the supplier of the data value contained in the property
Property: the RDF value of the metadata element
Sub-property of: a master RDF value that the property belongs to
Range: an indication of the data type of the value of the property
Usage: description of how the property should be used
Vocab Schema: a controlled vocabulary to be applied to the value of the property 
Syntax Schema: a syntax for the value of the property
Obligation: the requirement for the number of properties that can exist 

 


  • Event
LabelSourcePropertySub-property ofRangeUsageVocab SchemaSyntax SchemaObligationExample 1: FaultExample 2: CapacitorExample 3Example 4Note
Event_IDASPIRES.eventID  Unique identifier (ID) of the event file  112 4 
PQ monitor location Data provider.pqMonitorLocationCategory  Name of the utility substationSubstation, feeder, service entrance, equipment (cap., xfmr), load 0-1Service entranceService Entrance DataNode 5571 Service entrance

 

PQ monitor modelData provider.pqMonitorModel  Model of the PQ monitor  0-1Service Entrance I-Sense®  Schneider Electric Circuit Monitor 4000T (Square D) 
Nominal voltageData provider or ASPIRES.nominalVoltage  Nominal voltage of the system in kV   0-1   120 
Nominal frequencyData provider or ASPIRES.nominalFrequency  Nominal frequency of the system in Hertz50, 60 0-1   60 
Start timeData provider or ASPIRES.startTime  The start time of the event file in the ISO 8601 format 

ISO 8601

 

0-1

2003-02-02T 19:57:45.5000

 

 


2003-02-01T 03:54:06.4671 2003-02-26T15:54:17

 

date time offset (start time)ASPIRES.timeOffset  Time difference between the start time and a time value in a datasheet  0-100   
Time zoneData provider.timeZone  Time zone: PT, MT, CT, ET  0-1     
Root causeData provider.rootCause  Electrical incident triggering the event : short-circuit fault, energizing (capacitor, line, transformer), load change, generation  0-1     
Inferred root causeASPIRES.inferredRootCause  The root cause inferred using other properties.short-circuit fault, capacitor switching, ... 0-1Short-circuit faultCapacitor Switching Capacitor Switching 
Degree of certaintyASPIRES.certainty  Degree of certainty the recorded event was caused by the root causeHigh, medium, low 0-1     
Data provider (entity)ASPIRES.dataProvider  Name of the entity or organization providing the data to ASPIRES (may not be the data recording entity)  0-1ElectrotekElectrotek Electrotek 
Data sourceASPIRES or Data provider.dataSource  Name of the entity or organization that recorded the data (for example, a utility company). Could be the same as the data provider.  0-1     
Receiving database name and versionASPIRES or Data provider.receivedDatabase  Data Base name and version  0-1   Normal - PQView 3.46.0 Database - Version 3.03.04.00 
Providing agent (individual or official providing the data)Data provider.providingAgent  Name of the individual providing the data  

0-1

     
DetailData provider.detail  Additional details if available  0-1     
Containing datasetData provider.rawData  PQ event file or the database file which containts the PQ event, as received  0-1

PQViewAccess DB

(Not attached (100Mb))

PQViewAccess DB

(Not attached (100Mb))

   
VoltageData provider  Time-seriesVoltage data  1     
CurrentData provider  Time-seriesCurrent data  1     
DescriptionData provider  Description Additional description about the event  0-1     
Software analysisData provider or ASPIRES  Software analysis Software analysis performed on the event  0-1     
IEEE disturbance classificationASPIRES or Data Provider   IEEE Disturbance Category of this event according to the IEEE standard 1159-2009  0-n     

...

LabelSourcePropertySub-property ofRangeUsageVocab SchemaSyntax SchemaObligationExample: FaultExample: CapacitorExample 3Example 4Note
WeatherData Provider.weather arrayWeather category at the time when the data was recordedUnknown, wind, lightning, heat, ice/snow, rain, clear day, tornado/hurricane ## vocabularies used in PQ View Access database 0-1WindClear Day   
Isolation equipmentData Provider.isolationEquipment  Type of the protection equipment that cleared the disturbance event recorded in the event fileUnknown, breaker, recloser, fuse, sectionalizer, switch, elbow, network protectors ## vocabularies used in PQ View Access database  0-1FuseSwitch   
Internal agentData Provider.internalAgent  Equipment which failedCable, joint, transformer, conductor, splice, lightning arrester, switches, cross arm, pole, insulator, connector, other, unknown ## vocabularies used in PQ View Access database   0-1Lightning arresterCable   
External agent Data Provider.externalAgent  Factors from outside the power system which resulted in the root cause: Animals, lightning, wind, major event, scheduled, trees, overload, error, supply, equipment, other, unknown, earthquake ## vocabularies used in PQ View Access database   0-1TreeOverload Scheduled 
DetailData Provider.detail  Additional details if available Text0-1     

...