Next mount the media server so can add filesto the playback library.Note that files should be a .mp4 or .h264 of thestory package or PSA commercial to play duringthe newscastClick on>Go>Connect to Server |
|
Enter the IP address of the Caspar server -smb://192.168.1.1Click on ConnectThen put in the |
|
User Name and PW is taped to the computer monitorat the top of the screen |
|
Mount the volume share named ‘media’. |
|
If this is your first time logging into this system this semester then located on the volume share named ‘media’ is a folder named_NEED FOR DOCUMENTS FOLDER_Inside of that folder is a folder named SuperConductor. Copy that folder and paste it into your user’s Documents folder. |
|
Next look for the app namedSuperConductor in Applications |
|
Once SuperConductor is launched you should see a green indicator in the upper right corner that indicates you are connected to the Caspar server. If that indicator is red then you need to check the Bridges settings (see next item). |
|
If the indicator is red then select the Home tab and then select BridgesCheck to see if the IP address for the Caspar server is set to 192.168.1.1If it is not then you probably need to quit out of SuperConductor and copy the folder from 3 steps earlier over to your user Documents folder. Then go ahead and RESTART the entire computer. Don’t just log out, please REBOOT.If the IP address for the server is set to 192.168.1.1 and SuperConductor is still not connecting to the Caspar server then please request assistance. |
|
NextClick on LayersDVR A and B have settingsExample here is DVRB should be set toChanel 2 Layer 1 andCasparCG 2-1 should be set toChanel 2 Layer 1DVRA shouldbe set toChanel 1 Layer 1 andCasparCG 1-1 should be set toChanel 1 Layer 1 |
|
Next to add content to the Media serverSimply drag over the file to the media server as shownIf it does not load open QuickTime player and export outa 1080 file to recompress and it will fix the problem and thefile will show up in the app.QuickTime Player – Export a H264 file | |
The file should automatically show up in theSuperConductor library.hit refresh on SuperConductor |
|
Click on Default Rundown tab to use the rundown playback |
|
To delete a rundownClick on the RED trash can to delete |
|
Confirm you want to delete and click DELETE |
|
Tech Note:Check the 2nd Ethernet port that connects to the Caspar serverThis port must be set to the same IP range of the server.Caspar IP is 192.168.1.1Station 1 should be set to Manual IP192.168.1.5Station 2 should be set to Manual IP192.168.1.6 |
|