First make sure you can access this page "TechLinks"

You'll need lots of info from this page.

https://comm-fusion-p01.moody.utexas.edu/techlinks/

Now to access the touch panel setup information:


Press the buttons on the left-hand side of the Crestron room scheduler

in the order of top to bottom the first 4 buttons shown here.
Today = 1
Day < = 2
Day > = 3
Time = 4

Press them in sequence 1 – 4 (twice) in same order 1,2,3,4 (two) times

You should see

IP Address

Hostname

Mac Address

But if the touchpanel is offline you probably won't see this info


Click on IP Table Setup to look at the Host iP

 There are 3 important areas to notice here


CID:3

Host:

Online green or red?

 

In this example we are looking at CMA 3.108

Look at techlinks https://comm-fusion-p01.moody.utexas.edu/techlinks/

Look for CMA 3.108 to look at the information about the touchpanel

You will see all the info here that we

need to fix the touchpanel if it's offline

If in the case the touch panel looses connection and 

The HOST ip does not show any or the incorrect information

Check this with the information on Techlinks


In this example the Host has the correct IP it matches the 

Control system IP in the framegrab.  The IP of the Control System needs

to be entered in here for the Touchpanel to work

Port should always be 41794

If this doesn't have the same IP as what is listed for the

Control System in the techlinks then we need to change it.



Click on Add/Edit


Enter in the correct IP here

Choose Save

Choose Save Entry

Then Save and Exit to finish now touch panel should be back online