Off-Slit Guiding (for experts only)
In SVC Package window Nodding box, select the “Custom (see the advanced pane)” button.
At the bottom of the SVC Package window, click the “Advanced Pane” checkbox.
For Off-slit guiding we generally set “Every” underneath the “Stop Guide” button in the “Detector Control” box to 1.
In the Advanced Pane check the “Use Guide Position” checkbox
Under A-B Guide Box Position in the Advanced Pane…
For nodding on slit (ABBA)…
Make sure dA is set to -3.3 and 0.0 for SL and SW
Make sure dB is set to 3.3 and 0.0 for SL and SW
For nodding off (ON-OFF) slit with target centered on the slit …
Set dA to 0.0 and 0.0 for SL SW. This will put your target at the center of the slit.
Set dB to how far off you want to nod for the OFF. Make sure your guide star can still be seen. Alternatively you can manually nod to your OFF position using the digital hand paddle in the SVC Package. For example you could nod 300 arcsec North, take an off, then nod 300 arcsec South to go back. When you do this you need to move each time you change nods and take your A and B exposures one at a time.
Click the “Select A-B & Guide Box Position” button.
To set the guide box position…
Method 1: Unknown Offset (Target visible but faint) - click and guide. Off-slit guiding when you see the target and the guide star in a slit camera view but don't know the offsets.
Take a single SVC exposure
Place the target on the reference position by clicking the target, and "Go R" button. It should then say “R” under “Current.” Take another exposure. Repeat “Go R” and taking single exposures until your target is as well centered as you can get it on the little circle. This is important because you want to center your target as well as you can on the slit when taking its spectrum. Once you are satisfied the target is well centered, do not take any more exposures.
Click the guide star and then click the button "Sel G".
Make sure the pink box moved on to the guide star. If it is not perfect, repeat clicking the guide star and “Sel G” until you are satisfied the guide box crosshairs are centered on the guide star.
Click "Nod to A”. It should then say “A” under “Current.”
Method 2: Known Offset in Slit_length (dSL) and Slit_width (dSW) Off-slit guiding with known offsets in slit length and slit width between a target and a guide star.
IMPORTANT: Make sure in the “Move selected Target” box under “Current” it says A and not R. If it says R or ?, click SVC image near the slit, and then click the “go A” button.
Under A-B & Guide Box position in the Advanced Pane, set dG SL and SW do your desired values.
Click the “Select A-B & Guide Box Position” button.
Take a single SVC exposure
In the SVC image, click your guide star
Under “Guide Box Position” in the Advanced pane, click the button “Go G”
Make sure the guide box is centered on your guide star. If it is not perfect, take another SVC exposure, click the star, and then click the “Go G” button again. Repeat until you are satisfied the guide star is centered in the crosshairs of the guide box.
Take a single exposure. Check that the guide star is roughly centered in the guide box crosshairs. If it is not, click the star and click the button “Go G.”
Under “Device Control” click the button “Guide”. This will start the guiding.
Watch the guiding. Once you are satisfied the guiding is good, you can move over to the Data Taking Package and start your science exposures.
When you are finished taking data on a target, if your next target will use on slit guiding, reset the guiding settings.
Uncheck the “Use Guide Position” checkbox
Uncheck the “Advanced Pane” checkbox
In the nodding box, select “A-B”
Check that A and B boxes appear in the correct places over the slit
You can probably set “Every” under “Detector Control” back to 2 for on slit guiding