MPPT Integration Meeting Notes:
Custom MPPT:
Hardware:
Power: current plan is to power off of the LV power (12V) if we find a better reason to power the MPPT off of the array then we can adjust the plan
The reason for this is that the Blackbody A are changed off of the 12V so it would be more elegant
HV:
Integrate custom MPPT into the HV system for pre-charge
Isolate LV from HV
Next gen:
Use 12 V fuse box for power and CAN
12V → Isolated 12v → Hv system
Firmware:
Implement pre-charge protection
Commercial MPPT:
Hardware:
Powered off of CAN and 30V pre-charge
Minimum 6V
When testing it looked like it was drawing power from the array
HV:
Figure out if we can integrate both the commercial and custom MPPT into the HV system for pre-charge
Daybreak: Power off of 12V fuse box
Check to see if the CAN is isolated from the LV
If not:
We need an 12V isolator
Firmware:
Understand given firmware and implement pre-charge protection
Questions for TPEE :
Schematic?
Is CAN isolated from LV?