Bismuth Transfer Procedure

Bismuth Transfer Procedure

ESW 05/18/2017. Optimized by Sarah Muschinske Fall 2016 - Spring 2017. This is the optimized version.

Required Materials

  • As-grown Bi or BiSb on Si(111). 2 cm x 1 cm piece optimal for ease of transfer + efficient use of Bi / Si(111) wafer.

  • Nitto Denko single sided thermal release tape - 3.7 N/20mm tape used here (nominally releases at 90 C)

  • Transfer substrate (so far have used Si(111), SiO2/Si(100) with and without alignment markers, YIG, and glass slides).

Procedure

Setup

  • Turn on hot plate to 210 C

    • To standardize process, used aluminum foil-coated hot plate in bat cave fume hood

  • Quick solvent rinse of transfer substrates and as-grown Bi

    • Setup solvent rinse

      • Solvent hood E5 in main clean room

      • Set cloth chem wipe on outside of fume hood

      • Keep sample containers outside of fume hood to avoid contamination

      • Get out waste beaker kept in fume hood

    • Hold samples with metal tweezers and rinse over waste beaker

      • 15 s acetone

      • 30 s IPA

      • dry with N2 blow gun over chem wipe

    • Clean up hood

      • Pour waste liquid into large waste bottle to the side of the fume hood

      • Never pour solvent waste down the drain

      • Chem wipe in solvent waste container

  • Set up transfer area in bat cave

    • Transfer holder, scissors, tape, chem wipes

    • Do transfers in large sample holder to avoid tape sticking to wipes

    • Cut tape - about 1x width of sample, 1.5x length of sample

Bi delamination

  • Press tape piece onto sample, so that tape overhangs one end of sample

  • Smooth our any air bubbles gently with fingers

  • Turn sample over, and wedge plastic tweezers between Bi and tape

  • Firmly grip sample with tweezers, and pull tape quickly from overhanging end

  • Bi should be removed with the tape

Transfer to new substrate

  • Press Bi with tape onto second substrate (Bi-side down)

    • Pressing rather than rolling/smoothing motion avoids damaging Bi

  • Trim tape edges - this step is very important, as it prevents tape from sticking to / pushing Bi away from the hot plate, which can cause uneven heating

  • Put Tape/Bi/substrate stack onto pre-heated hot plate

  • Tape changes color as it releases - should happen very quickly

  • After release, remove Bi/substrate and tape from hot plate

Delamination Procedure Images

Align tape with as-grown BI
Press tape onto as-grown Bi
Wedge tweezers between Bi and tape
Firmly grip the Bi/Si(111) with the tweezers. Quickly pull the tape away from the susbtrate
Bi should be removed with the tape
Place Bi/tape onto new substrate, heat to release tape